Electrolytic cell
In situ Raman spectroscopy electrical test cell E702
1, can do lithium battery charge and discharge test; 2. To study the in situ spectrum of the material to be tested in the electrochemical test;
Key words:
In situ Raman spectroscopy electrical test cell E703
1. Can do lithium battery discharge test; 2. Study the in-situ spectrum of the material to be tested in electrochemical test;
Key words:
In situ Raman spectroscopy electrical test cell E704A
1, can be ventilated, can be tested under gas circulation conditions. 2, the negative electrode diaphragm protection, reduce the loss of the negative electrode, effectively extend the experimental time.
Key words:
In Situ Raman Spectroelectrochemical Cell K005
Suitable for installing sheet-like working electrodes, such as ITO,FTO conductive glass, various metal samples, etc., three electrodes, standard platinum-containing counter electrode and silver chloride reference, working samples prepared by themselves
Key words:
How to judge the electrolytic cell yin and yang pole?
First of all, look at whether [anode] is an inert electrode (it will be clearly stated in the question) if it is not an inert electrode, such as copper, then copper takes part in the reaction: Cu-2e = = = Cu2 if it is an inert electrode, then only the ion anode in the solution needs to be considered as anion and the cathode as cation anode
Key words:
The reference electrode is the electrode used as a reference for comparison when measuring various electrode potentials. The electrode to be measured and the reference electrode of the accurately known electrode potential value constitute a battery, and the electromotive force value of the battery can be measured to calculate the electrode potential of the measured electrode. The electrode reaction carried out on the reference electrode must be a single reversible reaction with stable electrode potential and good reproducibility. Usually, the slightly soluble salt electrode is used as the reference electrode, and the hydrogen electrode is only an ideal but not easy to realize reference electrode.
Key words:
Basic requirements for reference electrode
The reversibility of the electrode is better and it is not easy to be polarized. This requires that the reference electrode is reversible and the exchange current density is large (10-5A/cm2). When the current flowing through the electrode is less than 10 − 7A/cm2, the electrode is not polarized. Even if a slightly larger current flows for a short time, the potential can quickly return to the original value after the power is turned off.
Key words:
In situ Raman spectroscopy electrical test cell E702
Can do lithium battery discharge test; Study the in-situ spectrum of the material to be tested in the electrochemical test;
Key words:
In situ Raman spectroscopy electrical test cell E703
1. Can do lithium battery discharge test; 2. Study the in-situ spectrum of the material to be tested in electrochemical test;
Key words:
The difference between primary battery and electrolytic cell
Primary cell and electrolytic cell are two common electrochemical devices, which have some differences in structure and working principle.
Key words:
Latest Products